[b11] When b11 = 0 → 1: External command
positioning operation start
External command positioning operation is
performed. The rotation direction is determined
by the sign of the speed command.
For the details, see Section 6.3.
[b12] When b12 = 1: Variable speed operation
Variable speed operation is performed.
For the details, see Section 6.4.
< Operation command data transfer method >
X000
X001
X002
X003
X004
X005
X006
Start
X007
M8000
M2
M3
M4
M5
M6
M7
M8
M9
M1
M0
M10
M11
M12
M8000
RUN
monitor
Error reset
(M15~M 0) → BFM #25 (b15~b 0)
Stop command
Forward pulse stop
Reverse pulse stop
Jog+ operation
Jog- operation
Home position
return start
Relative/absolute
position
Single-speed
positioning
Interrupt single-
speed positioning
Two-speed
positioning
External command
positioning
Variable speed
operation
TO
K 0 K25 K4M0 K 1
Set only
one of
them to
ON.
(Normally
closed contact)
(Normally
closed contact)
5
FX-1PG/FX
2N
-1PG PULSE GENERATOR UNIT BFM LIST
5-11