9.3
Example of External Connection (MR-C Servo Amplifier)
*1 To release the alarm status, turn off the power, remove the cause of the alarm, then turn on the power again.
*2 The failure (ALM) signal is turned on in the normal status. When an alarm has occurred (the ALM signal is turned off),
stop pulse generation from the PGU using the program in the PC.
SG
FX
,
FX
2C,
FX
2N
Series PC
X10 X11 X12
Positioning
completed
Servo failure
PF
3
ALM
2
LSP LSN
Forward
limit
15 14
SON
17
SG
12
L1 L2
U V W
To servo motor
RA1 RA2
*2
MR-C¨A
MR-C¨A1
Servo amplifier
Servo ON
Parameter Pr16 is set
to "position servo".
MR-C¨A
MR-C¨A1
: Single-phase,
200V AC
: Single phase,
100V AC
RUN terminal is not provided
in FX
2N
, so this wiring is not
required in FX
2N
.
*1
RA1 RA2
24V DC power supply
0.2A or more
*3
Reverse
limit
SG terminal is not provided in
FX
2N
, so this wiring is not
required in FX
2N
.
L N 24V RUN X0 X1 X2 X3 X4 X5 X6 X7
STOPRUN
Error
reset
Forward
limit
Reverse
limit
JOG+
JOG-
Home
position
Start
S/S0V
Sensor
power supply
24V DC
9
FX-1PG/FX
2N
-1PG PULSE GENERATOR UNIT EXTERNAL CONNECTION EXAMPLES
9-5