9.2
Example of Connection Between FX
2N
-1PG and Stepper Motor
Extension cable
L N 24V X0 X1 X2 X3 X4 X5 X6 X7
STOP
Error
reset
Forward
limit
Reverse
limit
JOG+
JOG-
Home
position
Start
3.3k
FX
2N
Series PC
S/S0V
Sensor
power supply
24V DC
*1: The number of counts of zero signals is adjusted to 0 when there is no home position sensor.
At this time, when the dog input operates, the motor stops at once.
Make the home position return speed low-speed very because it does not destroy the machine.