*1 FX-1PG: Connect the VH terminal when the power is supplied from the MR-H. Connect either the
VH or VL terminal in accordance with the supply voltage when the power is supplied from an external
power supply. (See Section 8.1.)
FX
2N
-1PG: Connect the VIN terminal.
SG S/S DOG STOP *1 FP
COM0
RP
COM1
CLR PG0+ PG0-
SG NP1PP1SD OPP15R
LSD STOP
50 47 1918
SG terminal is not provided
in FX
2N, so this wiring is not
required in FX
2N.
Extension
cable
331
CRSG
3717
CN2
Encoder
24V DC
P C
Regenerative
option
FX-1PG
FX
2N-1PG
9
FX-1PG/FX
2N
-1PG PULSE GENERATOR UNIT EXTERNAL CONNECTION EXAMPLES