EasyManua.ls Logo

Mitsubishi PAJERO IV - C2. Check Parking Brake Lever Stroke and Play; C3. Replace Air Purifier Filter

Mitsubishi PAJERO IV
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATIONS INSIDE THE VEHICLE
PERIODIC INSPECTION AND MAINTENANCE
2-30
7. If the measured free play and distance do not
agree with the standard value ranges, it is
probably the result of either air in the hydraulic
system or a faulty master cylinder or clutch. Bleed
the air, or disassemble and inspect the master
cylinder or clutch.
8. Reinstall the carpet, etc.
C2. CHECK PARKING BRAKE LEVER
STROKE AND PLAY
M6020400200540
1. Pull the parking brake lever with a force of approx.
200 N and count the number of notches.
Standard value: 6 7 notches
2. If the parking brake lever stroke is not the
standard value, adjust as described below.
(1) Remove the cup holder, and then loosen the
adjusting nut to move it to the cable rod end so
that the cable will be free.
(2) Remove the rear wheels.
(3) Remove the adjustment hole plug of the rear
brake backing plate <Short wheelbase, Long
wheelbase-2800, 3000> or the rear brake disc
<Long wheelbase-3200, 3800>, and then use
a flat-tip screwdriver to turn the adjuster in the
direction of the arrow (the direction which
expands the shoe) so that the disc will not
rotate.
(4) Return the adjuster six notches <Short
wheelbase, Long wheelbase-2800, 3000> or
eight notches <Long wheelbase-3200, 3800>
in the direction opposite to the direction of the
arrow.
CAUTION
If the parking brake lever stroke is below the
standard value and the braking is too firm, the
rear brakes may drag.
(5) Turn the adjusting nut to adjust the parking
brake lever stroke to the standard value. After
adjusting, check that there is no space
between the adjusting nut and the parking
brake lever.
(6) Release the parking brake and turn the rear
wheels to check that the rear brakes are not
dragging.
C3. REPLACE AIR PURIFIER FILTER
M6020400300280
1. Remove the glove box.
2. Loosen the two screw as shown to replace the air
purifier filter.
3. Install the glove box.
AC608399
AB
Cable rod
Adjusting nut
AC604648
AC
<Short wheelbase, Long wheelbase-2 800, 3 000>
Adjuster
assembly
Backing
plate
AC604649
AD
Adjuster
assembly
Brake disc
<Long wheelbase-3 200, 3 800>
AC608840
AB

Table of Contents

Related product manuals