Appendix 2 Comparison of Qn(H)CPU and QnPRHCPU
APPENDICES
Table App.3 Comparison of Qn(H)CPU and QnPRHCPU (Continuation)
Item QnPRHCPU QnHCPU
System
Configuration
Multi CPU System N/A Applicable
Single CPU System Applicable (Debug mode only) Applicable
GOT
Connection
Type
Bus Connection N/A Applicable
CPU Direct
Connection
Applicable (Communication with the CPU module connected to
the GOT only)
Applicable
Computer Link
Connection
N/A Applicable
Ethernet
Connection
Applicable Applicable
CC-Link IE
Controller
Network
Connection
Applicable (N/A for extension base unit) Applicable
MELSECNET/
H PLC to PLC
Network
Connection
Applicable (N/A for extension base unit) Applicable
CC-Link
Connection
Applicable Applicable
MELSECNET/H
Remote I/O
Station
Connection
Applicable (N/A for extension base unit) Applicable
Mounting I/O module or
network module on slot 0
Disabled (Slot 1 becomes I/O number "0")
Mount I/O modules and network modules on slots 1 and
later.
Enabled
Restriction on the
applicable intelligent
function modules
Applied
The Ethernet modules and MELSECNET/H
modules of serial No. "06052" or later are
applicable.
Not applied
Programming
Too l
GX Developer Version 8.18U or later is applicable Version 4 or later is applicable.
Program
Instruction restriction
Instructions shown in Table App.4 cannot be used.
Instructions shown in Table App.5 can be used under
restrictions.
Floating point calculations
Only internal operation processing with single
precision.
(Internal operation processing precision level (single/
double) is not selectable)
Internal operation processing precision
level (single/double) is selectable.
High-speed interrupt (I49) N/A Applicable
Slow-speed execution-type
program
N/A Applicable

Table of Contents