5 - 38 
MELSEC-Q
5   DATA USED FOR POSITIONING CONTROL 
 
Pr.36
Sudden stop deceleration time 
Set the time to reach speed 0 from "
Pr.8
Speed limit value" (or "
Pr.31
JOG 
speed limit value" during JOG operation) during the sudden stop.  
The illustration below shows the relationships with other parameters. 
 
When positioning is started, 
the acceleration starts following
the "acceleration time".
1) Positioning start
2) Sudden stop cause occurrence
When a "sudden stop cause" occurs, 
the deceleration starts following the 
"sudden stop deceleration time".
3) Positioning stop
When a "sudden stop cause" 
does not occur, the decelera-
tion starts toward the stop 
position following the "decel-
eration time".
Actual accel-
eration time
Actual sudden stop 
deceleration time
Acceleration time
Actual decel-
eration time
Deceleration time
Speed limit 
value
Pr.8
Command 
speed
Da.8
Pr.36
Sudden stop
deceleration time
Acceleration time 0
Pr.9
Acceleration time 1
Pr.25
Acceleration time 2
Pr.26
Acceleration time 3
Pr.27
Deceleration time 0
Pr.10
Deceleration time 1
Pr.28
Deceleration time 2
Pr.29
Deceleration time 3
Pr.30