5 - 104
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.7 List of control data
5.7.1 System control data
Setting item Setting details
Cd.1
Flash ROM write request
Requests writing of data (parameters, positioning data, and block start data) from
the buffer memory to the flash ROM.
Requests initialization of setting data.
Initialization: Resetting of setting data to default values
Note: After completing the initialization of setting data, reset the CPU module or
reboot the programmable controller power.
Initialized setting data
Parameters (
Pr.1
to
Pr.57
, Pr.150 )
Positioning data (No. 1 to No. 600)
Block start data (No. 7000 to 7004)
Cd.2
Parameter initialization request
Cd.41
Deceleration start flag valid
Set whether "
Md.48
Deceleration start flag" is made valid or invalid.
Cd.42
Stop command processing for
deceleration stop selection
Set the stop command processing for deceleration stop function (deceleration
curve re-processing/deceleration curve continuation).