5 - 64 
MELSEC-Q
5   DATA USED FOR POSITIONING CONTROL 
 
[Table 1] 
 
 When "
Pr.1
Unit Setting" is "mm" 
The table below lists the control systems that require the setting of the arc address 
and shows the setting range. 
(With any control system excluded from the table below, the arc address does not 
need to be set.) 
 
Da.2
setting value 
Value set with peripheral device 
(
μ
m) 
Value set with sequence program 
1 
(
10
-1
μ
m) 
ABS circular sub  : 0DH 
ABS circular right  : 0F
H 
ABS circular left  : 10
H 
 Set the address 
  -214748364.8 to 214748364.7 
 Set the address 
  -2147483648 to 2147483647 
INC circular sub  : 0EH 
INC circular right  : 11
H 
INC circular left  : 12
H 
 Set the movement amount 
  -214748364.8 to 214748364.7
 
 Set the movement amount 
  -2147483648 to 2147483647
 
1:  Set an integer because the sequence program cannot handle fractions. 
(The value will be converted properly within the system.) 
2:  Note that the maximum radius that circular interpolation control is possible is 536870912, although the setting value 
can be input within the range shown in the above table, as an arc address. 
 
 When "
Pr.1
Unit Setting" is "degree" 
No control system requires the setting of the arc address by "degree". 
 
 When "
Pr.1
Unit Setting" is "pulse" 
The table below lists the control systems that require the setting of the arc address 
and shows the setting range. 
(With any control system excluded from the table below, the arc address does not 
need to be set.) 
 
Da.2
setting value 
Value set with peripheral device  
(pulse) 
Value set with sequence program 
1 
(pulse) 
ABS circular sub  : 0DH 
ABS circular right  : 0F
H 
ABS circular left  : 10
H 
 Set the address 
  -2147483648 to 2147483647 
 Set the address 
  -2147483648 to 2147483647 
INC circular sub  : 0EH 
INC circular right  : 11
H 
INC circular left  : 12
H 
 Set the movement amount 
  -2147483648 to 2147483647
 
 Set the movement amount 
  -2147483648 to 2147483647
 
1:  Set an integer because the sequence program cannot handle fractions. 
(The value will be converted properly within the system.) 
2:  Note that the maximum radius that circular interpolation control is possible is 536870912, although the setting value 
can be input within the range shown in the above table, as an arc address. 
 
 When "
Pr.1
Unit Setting" is "inch" 
The table below lists the control systems that require the setting of the arc address 
and shows the setting range. 
(With any control system excluded from the table below, the arc address does not 
need to be set.) 
 
Da.2
setting value 
Value set with peripheral device  
(inch) 
Value set with sequence program 
1  
(×10
-5
 inch) 
ABS circular sub  : 0DH 
ABS circular right  : 0F
H 
ABS circular left  : 10
H 
 Set the address 
  -21474.83648 to 21474.83647 
 Set the address 
  -2147483648 to 2147483647 
INC circular sub  : 0EH 
INC circular right  : 11
H 
INC circular left  : 12
H 
 Set the movement amount 
  -21474.83648 to 21474.83647
 
 Set the movement amount 
  -2147483648 to 2147483647
 
1:  Set an integer because the sequence program cannot handle fractions. 
(The value will be converted properly within the system.) 
2:  Note that the maximum radius that circular interpolation control is possible is 536870912, although the setting value 
can be input within the range shown in the above table, as an arc address.