5   DATA USED FOR POSITIONING CONTROL 
 
Storage item  Storage details 
 
 
 
 
 
Md.28
 Axis feedrate 
•
  The speed which is actually output as a command at that time in each axis is 
stored. (May be different from the actual motor speed) 
"0" is stored when the axis is at a stop. 
Update timing: 0.9ms (QD75P
N/QD75D N), 56.8ms (QD75P /QD75D ) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Md.29
 Speed-position switching 
control positioning amount 
•
  The movement amount for the position control to end after changing to position 
control with the speed-position switching control (INC mode) is stored. When the 
control method is "Reverse run: position/speed", the negative value is stored. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Md.30
 External input/output signal 
The ON/OFF state of the external input/output signal is stored. 
The following items are stored. 
•
  Upper limit signal 
•
  Lower limit signal 
•
 Drive unit READY signal 
•
 Stop signal 
•
 External command signal 
•
 Zero signal 
•
  Near-point dog signal 
•
  Deviation counter clear signal  
Update timing: 0.9ms (QD75P
N/QD75D N), 56.8ms (QD75P /QD75D )