5 - 109 
MELSEC-Q
5   DATA USED FOR POSITIONING CONTROL 
 
 
Storage buffer  
memory address 
 
 
 
 
 
Setting value 
Default 
value 
Axis 1  Axis 2  Axis 3 Axis 4
 
 
 
 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
Setting
alue
 
   Positioning data No.
1 to 600
7000 to7004
9001
9002
9003
9004
K
: Positioning data No.
: Block start designation
: Machine OPR
: Fast-OPR
: Current value changing
: Simultaneous starting of multiple axes
 
 
0 1500 1600 1700 1800
 
 
 
 
 
 
 
 
 
 
 
Set with a decimal.
 
Setting 
value
K
1 to 50
Positioning starting point  No.
 
0 1501 1601 1701 1801
 
 
 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
 
 
K
1
Error reset request 
etting value
fter the axis error reset is completed, "0" is stored by the QD75 automatically. 
Indicates that the axis error reset is com
leted.
1: Axis error is reset.
  
 
0 1502 1602 1702 1802
 
 
 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
 
 
K
 
1
Restart command 
Setting value
After restart acceptance is completed, "0" is stored by the QD75 automatically. 
(Indicates that the restart acceptance is completed.)
1: Restarts 
 
 
0 1503 1603 1703 1803
 
 
 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
 
 
 
K
 
1
M code OFF request 
Setting value
After the M code ON signal turns OFF, "0" is stored by the QD75 automatically. 
Indicates that the OFF re
uest is com
leted.
1: M code ON signal turns OFF
 
 
0 1504 1604 1704 1804