5 - 123
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Storage buffer
memory address
Setting value
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
Set with a decimal.
Setting
value
Position-speed switching enable flag
0: Position control will not be taken over by speed
control even when the external command signal
[CHG] comes ON.
1: Position control will be taken over by speed
control when the external command signal [CHG]
comes ON.
K
0 1532 1632 1732 1832
0
1534
1535
1634
1635
1734
1735
1834
1835
Set with a decimal.
Actual value
R
Setting value
(Decimal)
10
n
n
-1
m
-5
inch
-5
degree
0
pulse
Unit
n
-2
mm/min
-3
inch/min
-3
degree/min
0
pulse/s
Unit
Conversion into an integer value
Unit conversion table ( Cd.27 )
Unit conversion table ( Cd.28 )
Cd. 27 Target position change value (address)
Cd. 28 Target position change value (speed)
Example: If " Cd. 28 Target position change
value (speed) is set as "10000.00
mm/min", the buffer memory stores
"1000000".
0
1536
1537
1636
1637
1736
1737
1836
1837
Set with a decimal.
Setting
value
K
1
1: Requests a target position change
Target position change request flag
The QD75 resets the value to "0" automatically
when the new target position value has been written.
(This indicates the completion of target position change request.)
0 1538 1638 1738 1838