6 - 36
MELSEC-Q
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
[2] Starting by inputting external command signal
When starting positioning control by inputting the external command signal, the
start command can be directly input into the QD75. This allows the variation time
equivalent to one scan time of the CPU module to be eliminated. This is an
effective procedure when operation is to be started as quickly as possible with
the start command or when the starting variation time is to be suppressed. To
start positioning control by inputting the external command signal, set the "data
required to be set" and then turn ON the external command signal.
Restrictions
When starting by inputting the external command signal, the start complete signal
[X10, X11, X12, X13] will not turn ON.
Data required to be set
To execute positioning start with the external command signal, set parameter
(
Pr.42
) beforehand, and validate the "external command signal" with the
"External command function valid setting program (program No. 5)".
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3 Axis 4
Pr.42
External command
function selection
0 Set to "0: External positioning start". 62 212 362 512
Cd.8
External command valid 1 Set to "1: Validate external command". 1505 1605 1705 1805
Refer to CHAPTER 5 "DATA USED FOR POSITIONING CONTROL" for details on the setting details.
Starting time chart
0
V
t
1(00)
External command signal
1
01
Cd. 8 External command valid
Dwell time
Operation pattern
Positionin
g
start si
g
nal
PLC READY si
g
nal
QD75 READY si
g
nal
Start complete si
g
nal
BUSY si
g
nal
Error detection si
g
nal
Positionin
g
complete si
g
nal
Positioning data No.
Pr. 42 External command function selection
Cd. 3 Positioning start No.
[Y10]
[Y0]
[X0]
[X10]
[XC]
[X14]
[X8]
Fig. 6.11 Time chart for starting with external start signal