9 - 7 
MELSEC-Q
9   MAJOR POSITIONING CONTROL 
 
[2]   Continuous positioning control 
 
(1)  The machine always automatically decelerates each time the positioning is 
completed. Acceleration is then carried out after the QD75 command speed 
reaches 0 to carry out the next positioning data operation. If a dwell time is 
designated, the acceleration is carried out after the designated time elapses.  
(2)  In operation by continuous positioning control (operation pattern "01"), the 
next positioning No. is automatically executed. Always set operation pattern 
"00" in the last positioning data to complete the positioning.  
  If the operation pattern is set to positioning continue ("01" or "11"), the 
operation will continue until operation pattern "00" is found.  
  If the operation pattern "00" cannot be found, the operation may be carried 
out until the positioning data No. 600. If the operation pattern of the 
positioning data No. 600 is not completed, the operation will be started again 
from the positioning data No. 1. 
 
Time
OFF
ON
OFF
ON
OFF
ON
OFF
Positioning continue (01)
Address (+) direction 
Address (-) direction
Positioning
complete (00) 
Dwell
time
ON
Positioning continue (01)
Start complete signal
BUSY signal
Positioning complete signal
Positioning start signal
[Y10, Y11, Y12, Y13]
[X10, X11, X12, X13]
[XC, XD, XE, XF]
[X14, X15, X16, X17]
Dwell time
not designated
 
Fig. 9.2 Operation during continuous positioning control