9 - 37 
MELSEC-Q
9   MAJOR POSITIONING CONTROL 
 
[2]   3-axis linear interpolation control (INC linear 3) 
 
 Operation chart 
 
In incremental system 3-axis linear interpolation control, designated 3 axes are 
used. Linear interpolation positioning of movement amount set in "
Da.6
 
Positioning address/movement amount" is carried out from the current stop 
position (start point address). The movement direction is determined by the sign of 
the movement amount. 
 
 axis
movement amount
X axis movement
amount
Y axis movement amount
Start point address (X1, Y1, Z1)
(current stop position)
Forward direction
Forward direction
Forward direction
Movement by linear interpolation
positioning of the X axis, Y axis and Z axis
Z
2
Y
2
X
2
Reverse direction
Reverse direction
Reverse direction
 
 
When the axis 1 movement amount is 10000, the axis 2 movement amount is 5000 and the axis
3 movement amount is 6000, positioning is carried out as follows.
Start point address
(current stop position)
Axis 1
Axis 3
Stop address after the positioning control
6000
Axis 2
Axis 3 movement
amount (6000)
5000
Axis 2 movement amount
(5000)
5000 10000
Axis 1 movement amount (10000)
Example