9 - 47 
MELSEC-Q
9   MAJOR POSITIONING CONTROL 
 
 Positioning data setting example 
 
[Reference axis and interpolation axis are designated as axis 1 and axis 2, 
respectively.] 
The following table shows setting examples when "2-axis fixed-dimension feed 
control (fixed-feed 2)" is set in positioning data No. 1 of axis 1. (The required 
values are also set in positioning data No. 1 of axis 2.) 
 
Axis 
 
Setting item 
Axis 1 
(reference 
axis) setting 
example 
Axis 2 
(interpolation 
axis) setting 
example 
Setting details 
Da.1
 
Operation pattern 
Positioning 
complete 
– 
Set "Positioning complete" assuming the next positioning 
data will not be executed. 
Da.2
 
Control system  Fixed-feed 2  –  Set 2-axis fixed-feed control. 
Da.3
 
Acceleration time 
No. 
1 – 
Designate the value set in "
Pr.25
 Acceleration time 1" as 
the acceleration time at start. 
Da.4
 
Deceleration time 
No. 
0 – 
Designate the value set in "
Pr.10
 Deceleration time 0" as 
the deceleration time at deceleration. 
Da.5
 
Axis to be 
interpolated 
Axis 2 
– 
Set the axis to be interpolated (partner axis). 
If the self-axis is set, an error will occur. 
Da.6
 
Positioning address/ 
movement amount 
8000.0 
μ
m 6000.0 
μ
m
Set the positioning address. (Assuming "mm" is set in 
"
Pr.1
 Unit setting".) 
Da.7
 
Arc address  –  –  Setting not required (setting value will be ignored). 
Da.8
 
Command speed 
6000.00 
mm/min 
– 
Set the speed during movement. (Designate the composite 
speed of reference axis speed in "
Pr.20
 Interpolation 
speed designation method".) 
Da.9
 
Dwell time  500ms  – 
Set the time the machine dwells after the positioning stop 
(pulse output stop) to the output of the positioning complete 
signal. 
Axis 1   Positioning data No. 1 
Da.10
 
M code  10  – 
Set this when other sub operation commands are issued in 
combination with the No. 1 positioning data. 
 
   * Refer to Section 5.3 "List of positioning data" for information on the setting details.