9 - 52
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Axis 3
(interpolation
axis) setting
example
Setting details
Da.1
Operation pattern
Positioning
complete
– –
Set "Positioning complete" assuming the next
positioning data will not be executed.
Da.2
Control system Fixed-feed 3 Set 3-axis fixed-feed control.
Da.3
Acceleration time
No.
1 –
Designate the value set in "
Pr.25
Acceleration time 1" as the acceleration time
at start.
Da.4
Deceleration time
No.
0 –
Designate the value set in "
Pr.10
Deceleration time 0" as the deceleration time
at deceleration.
Da.5
Axis to be
interpolated
– –
Setting not required (setting value will be
ignored).
When axis 1 is used as a reference axis, the
interpolation axes are axes 2 and 3.
Da.6
Positioning address/
movement amount
10000.0
μ
m 5000.0
μ
m 6000.0
μ
m
Set the positioning address. (Assuming "mm"
is set in "
Pr.1
Unit setting".)
Da.7
Arc address
Setting not required (setting value will be
ignored).
Da.8
Command speed
6000.00
mm/min
Set the speed during movement.
Da.9
Dwell time 500ms
Set the time the machine dwells after the
positioning stop (pulse output stop) to the
output of the positioning complete signal.
Axis 1 Positioning data No. 1
Da.10
M code 10
Set this when other sub operation commands
are issued in combination with the No. 1
positioning data.
Refer to Section 5.3 "List of positioning data" for information on the setting details.