9 - 111 
MELSEC-Q
9   MAJOR POSITIONING CONTROL 
 
(4)  If the value set in "
Da.6
 Positioning address/movement amount" is outside 
the software stroke limit (
Pr.12
,
Pr.13
) setting range, an error "Software 
stroke limit +" or "Software stroke limit –" (error code: 507 or 508) will occur at 
the positioning start, and the operation will not start.  
 
(5)  An error "Software stroke limit +" or "Software stroke limit –" (error code: 507 
or 508) will occur if the new current value is outside the software stroke limit 
range. 
 
 Positioning data setting examples 
The following table shows the setting examples when " current value changing" is 
set in the positioning data No. 1 of axis 1. 
 
Setting item  Setting example  Setting details 
 Da.1 
 
Operation 
pattern 
Positioning complete 
Set "Positioning complete" assuming that 
the next positioning data will be executed. 
("Continuous path control" cannot be set by  
current value change.) 
 Da.2 
 
Control 
system 
Current value changing  Set the current value changing. 
 Da.3 
 
Acceleration 
time No. 
– 
Setting not required (Setting value is 
ignored.) 
 Da.4 
 
Deceleration 
time No. 
– 
Setting not required (Setting value is 
ignored.) 
 Da.5 
 
Axis to be 
interpolated 
– 
Setting not required (Setting value is 
ignored.) 
 Da.6 
 
Positioning 
address/ 
movement 
amount 
10000.0
m 
Set the address to which address change is 
desired. (Assuming that the "
Pr.1
 Unit 
setting" is set to "mm".) 
 Da.7 
 
Arc address  – 
Setting not required (Setting value is 
ignored.) 
 Da.8 
 
Command 
speed 
– 
Setting not required (Setting value is 
ignored.) 
 Da.9 
 
Dwell time  – 
Setting not required (Setting value is 
ignored.) 
Axis 1 
positioning 
data No. 1 
 Da.10 
 
M code  10 
Set this when other sub operation 
commands are issued in combination with 
the No. 1 positioning data. 
 
 Refer to Section 5.3 "List of positioning data" for information on the setting details.