12 - 17 
MELSEC-Q
12   CONTROL SUB FUNCTIONS 
 
[2]   Error compensation method 
When position control is carried out by the "movement amount per pulse" set in 
the QD75 parameters, an error sometimes occurs between the command 
movement amount (L) and the actual movement amount (L').  
That error is compensated in the QD75 by adjusting the values in "
Pr.2
 No. of 
pulses per rotation (Ap)", "
Pr.3
 Movement amount per rotation (Al)", and 
"
Pr.4
 Unit magnification (Am)". (When " Pr.1  Unit setting" is "0: mm") 
(1)   Definition 
The "error compensation amount" used to carry out the error compensation 
is defined as follows.  
 
Actual movement amount (L') 
Error compensation amount = 
Designated movement amount (L) 
 
The QD75 "movement amount per pulse" is calculated with the following 
equation.  
Movement amount per pulse is "A", "
Pr.2
 No. of pulses per rotation" is 
(Ap), "
Pr.3
Movement amount per rotation" is (Al), and "
Pr.4
 Unit 
magnification" is (Am).  
 
Al 
A =
Ap 
 
 Am 
 
(2)   Procedure  
(a)  Set the "command movement amount (L)", and carry out positioning.  
(Set the "movement amount per pulse (A)" according to Section 5.2 
"List of parameters".) 
 
(b)  After positioning, measure the "actual movement amount (L')".  
 
(c)  Calculate the "error compensation amount".  
 
L' 
Error compensation amount =
L 
 
(d)  Calculate the post-compensation "
Pr.2
 No. of pulses per rotation 
(Ap')", "
Pr.3
 Movement amount per rotation (Al')", and "
Pr.4
 Unit 
magnification (Am')" from the "post-compensation movement amount 
per pulse (A')".  
 
A = A 
 
 Error compensation amount 
 
Al L' 
=
Ap 
 
 Am 
L 
 
Al' 
=
Ap' 
 
 Am' 
 
(Adjust with Am' so that Al' and Ap' do not exceed the setting range.)