12 - 56 
MELSEC-Q
12   CONTROL SUB FUNCTIONS 
 
[2]   Control precautions 
(1)  If a value besides "0" is set in the "
Cd.22
 New torque value", the torque 
generated by the servomotor will be limited by that value. To limit the torque 
with the value set in "
Pr.17
 Torque limit setting value", set the "
Cd.22
 
New torque value" to "0".  
 
(2) The "
Cd.22
 New torque value" is validated when written to the QD75. 
(Note that it is not validated from the time the power supply is turned ON to 
the time the PLC READY signal (Y0) is turned ON.) 
 
(3)  If the setting value is outside the setting range, an axis warning "Outside 
new torque value range" (warning code: 113) will occur and the torque will 
not be changed. 
 
(4)  If the time to hold the new torque value is not more than 100ms, a torque 
change may not be executed. 
 
[3]   Setting method 
To use the "torque change function", write the data shown in the following table 
to the QD75 using the sequence program.  
The set details are validated when written to the QD75.  
 
Buffer memory address
Setting item 
Setting 
value 
Setting details 
Axis 
1 
Axis 
2 
Axis 
3 
Axis 
4 
Cd.22
 
New torque value 
 
Set the new torque limit value.  1525  1625  1725 1825
 