12 - 108
MELSEC-Q
12 CONTROL SUB FUNCTIONS
[3] Setting method
To use the "stop command processing for deceleration stop function", set the
following control data in a sequence program.
The set data are made valid as soon as they are written to the buffer memory.
The PLC READY signal [Y0] is irrelevant.
Setting item
Setting
value
Setting details Buffer memory address
Cd.42
Stop command
processing for
deceleration stop
selection
Set the stop command processing for
deceleration stop function.
0: Deceleration curve re-processing
1: Deceleration curve continuation
1907
For details of the setting details, refer to "Section 5.7 Control data list".