15 - 17
MELSEC-Q
15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Set range
(Setting with sequence program)
Remedy
Refer to Section 5.4
"List of block start data"
<Condition data No.>
1 to 10
Review the condition data No.
(Refer to Section 5.4
Da.14
)
Refer to Section 5.5
"List of condition data"
<Condition operators>
Axis designation:
10
H, 20H, 30H, 40H, 50H,
60H, 70H, 80H, 90H, A0H,
B0
H, C0H, D0H, E0H
Normalize the condition operators.
(Refer to Section 5.5
Da.16
)
1540 1640 1740 1840 Axis 1 start data No.
1541 1641 1741 1841 Axis 2 start data No.
1542 1642 1742 1842 Axis 3 start data No.
1543 1643 1743 1843 Axis 4 start data No.
Simultaneous
start axis start
data No.
0 to 600
Normalize the simultaneous start axis start data No.
(Refer to Section 10.5)
1500 1600 1700 1800
<Positioning start No.>
1 to 600,
7000 to 7004,
9001 to 9004
<JUMP destination>
1 to 600
Normalize the positioning start No., positioning start
data (in block start), and positioning data (in JUMP
instruction).
Refer to Section 5.3
"List of positioning data"
<Command speed>
QD75P
N/QD75D N:
1 to 4000000 [pulse/s]
1 to 2000000000
[
10
-2
mm/min or others]
QD75P
/QD75D :
1 to 1000000 [pulse/s]
1 to 2000000000
[
10
-2
mm/min or others]
Normalize the positioning data.