EasyManua.ls Logo

Mitsubishi QD75P1N - Page 663

Mitsubishi QD75P1N
858 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15 - 25
MELSEC-Q
15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Set range
(Setting with sequence program)
Remedy
Command speed storage
addresses of positioning
data No. 1 to 600
<Command speed>
QD75P
N/QD75D N:
1 to 4000000 [pulse/s]
1 to 2000000000
[
×
10
-2
mm/min or others]
QD75P /QD75D :
1 to 1000000 [pulse/s]
1 to 2000000000
[
×
10
-2
mm/min or others]
Correct the command speed.
(Refer to Section 5.3
Da.8
)
29 179 329 479
<Interpolation speed designation
method>
0: Composite speed
1: Reference axis speed
Set the "Interpolation speed designation method"
correctly.
(Refer to Section 9.1.6)
Same as error codes 515 to 516
• Correct the control system axis to be interpolated, or
parameter.
(Refer to Section 9.1.6, 9.2.20)
• Do not make setting at buffer memory address 1906
(use prohibited area).
Refer to Section 5.3
"List of positioning data"
<Positioning address/movement
amount>
• unit [mm] [pulse] [inch]
–2147483648 to 2147483647
(Unit [degree] cannot be set.)
<Arc address>
–2147483648 to 2147483647
Correct the sub address (arc address).
(Refer to Section 9.2.10)

Table of Contents