9 LONG-TERM STORAGE
Mitsubishi Diesel Engine S12R OPERATION & MAINTENANCE MANUAL
174
Pub. No. 291Y1-40720 Revision: 5
9 Apply engine oil on the valve
mechanisms of all the cylinder
heads.
Tool: Oiler, oil jug, and others.
Fig. 9-2 Engine Oil - Apply (Valve Mechanism)
10 Install the rocker covers onto all the
cylinder heads.
Tool: Wrench
Fig. 9-3 Rocker Cover - Install
Restart
1 Pull the manual stop lever in the
direction of stopping and hold this
position, and crank the engine for
approx. 10 seconds using the
starter.
Fig. 9-4 Restart after Storing
The location of the manual stop lever
varies depending on the specification
of the engine. Refer to "
Protection
System - Location" ( Page 82).
2 Pause for about 1 minute.
3 Repeat the operation of Step 1 and 2
for 2 or 3 times.
4 After starting the engine, make sure
that the engine oil pressure rises
with a pressure gauge.
5 Conduct a warm-up operation for a
sufficient duration to fully lubricate
all the components.
6 Operate the engine under load.
Storing Engine in Operable
Condition
Perform maintenance operation "Maintenance
Operation" ( Page 102) once a month.