11 TROUBLESHOOTING
Mitsubishi Diesel Engine S12R OPERATION & MAINTENANCE MANUAL
182
Pub. No. 291Y1-40720 Revision: 5
Output Shortage
Table 11-3 Output Shortage (1/2)
Problem Cause Remedies Reference
Page
Output Shortage Fuel System Improper fuel
properties
Change with appropriate fuel. 103
Faulty fuel injec-
tion timing
Check fuel injection pump drive
coupling.
-
Contact your MHIET dealer. 10
Improper maxi-
mum injection vol-
ume
Fuel System - Bleed Air 134
Check fuel injection pump rack
stroke.
Check the balance between left
and right banks.
-
Contact your MHIET dealer. 10
Clogged fuel filter Check and replace fuel filter. 140
Gauze Filter - Clean 139
Change to fuel suitable for the
ambient temperature.
103
Fuel feed pump
malfunction
Contact your MHIET dealer. 10
Cooling System Overheating Refer to the items of overheating. 189
Overcooling Check fan and heat exchanger.
Check control system.
-
Contact your MHIET dealer. 10
Intake and
Exhaust
Systems
Insufficient
amount of intake
air
Turbocharger - Check 165
Clean, check and replace pre-
cleaner.
166
Clean, check and replace air
cleaner element.
Check intake air pressure and
leakage of intake air.
Check intake air temperature and
ventilation device.
167
Contact your MHIET dealer. 10
Increase of ex-
haust resistance
Turbocharger - Check
Check exhaust pipes, muffler and
silencer.
165
Contact your MHIET dealer. 10

Table of Contents