1 SAFETY
Mitsubishi Diesel Engine S12R OPERATION & MAINTENANCE MANUAL
65
Pub. No. 291Y1-40720 Revision: 5
Develop the Action Procedure
to Obey in the Event of
Emergency
It is important to create the action procedure for
emergency situations to rescue and assist the
operators involved in an accident.
Examples of the items that should be included in
the action procedure of emergency are shown
below as a reference.
(a) Appointment of a contact person as an
assistant person for rescue work.
(b) Include at least one rescue trained person in
each work party.
(c) Preparation of suitable tools and equipment
required for rescue work
Keep Everyone Informed about
the Emergency Stop Procedure
Compile the information about the protection
devices, fuel, engine oil, pipings of the cooling and
inlet/exhaust system installed during manufacturing
the generator and attach it on the next page.
Also ensure that their locations and function are
instructed to, and understand by the operators in
addition to the details of the "Safety Manual".
Measures in the Event of
Emergency
Emergency Stop Procedure
Thoroughly understand the stopping procedure to
be followed in the event of emergency.
1 Use the emergency stopping devices
of the generator "
Emergency
Stopping Devices Installed during
Manufacturing the Generator" (→
Page 66).
2 If the engine does not stop, pull the
manual stop lever of the engine in
the stop direction, and hold the lever
in this position.
Fig. 1-9 Emergency Stop Procedure
• The location of the manual stop lever
varies depending on the specification
of the engine. Refer to "
Protection
System - Location" (→ Page 82).
3 After the engine has stopped
completely, release the manual stop
lever.
Prepare first-aid kits and first aid
tools.
* Otherwise, in case of personal injury, first aid
treatment can be delayed, which may cause
death in the worst case.
Prepare an emergency action plan in
the event of emergency (fire,
accidents, etc.) including emergency
contact points and means of
communication.
* Delay in action may result in expansion of
damage.
When stopping the engine by pulling
the manual stop lever, keep pulling
the lever until the engine stops
completely.
* Otherwise, the engine may start again.
If the stop switch of the generator will
not function and the engine will not
stop by using the manual stop lever,
shut off fuel supply.
* Otherwise, extent of the damage may increase.
䣕䣖䣑䣒
䣕䣖䣑䣒䣕䣖䣑䣒