SECTION
Ill
EMERGENCY PROCEDURES
MOONEY
M20J
FIRES
ENGINE FIRE-GROUND
..........
Mixture IDLE CUTOFF (Full Aft)
..............
Fuel Selector Valve .OFF
............
MagnetoIStarter Switch .OFF
...............
Master Switch .OFF
Fire
, ,
.
,
. .
,
.
Extinguish with Fire Extinguisher
ENGINE FIRE-IN FLIGHT
.........
Fuel Selector Valve
..........
Throttle
..........
Mixture Control
MagnetolStarter Switch
.......
Cabin Ventilation
&
Heating Controls
.,.
..........
Cowl Flaps
.........
..........
banding Gear
........
Wing Flaps
........
--------
I
NOTE
I
.
.OFF
.
.
CLOSED (Full
Aft)
IDLE CUTOFF (Full Aft)
.
.OFF
.
,
.
.
CLOSED
,
.
(Controls Forward)
.
,
.
.
CLOSED
, ,
.DOWN or UP,
.
depending on terrain
.
,
,
.
EXTEND
..
as necessary
If
fire is not extinguished, attempt lo increase airflow over the
engine by increasing glide speed and open cowl flaps.
Proceed with
a
POWER OFF landing as described on page
3-18.
Do not attempt an engine restart.
ELECTRICAL FIRE-
IN
FLIGHT (Smoke in Cabin)
..............
Master Switch .OFF
llllll/l/llllllllllli/
///WARNING///
////////I/////////////
Stall warning is not available with master switch OFF. Gear
warning is not available with master switch OFF.
..............
Cabin Ventilation OPEh*
........
Heating Controls CLOSED (Control Forward)
..........
Circuit Breakers
CHECK to identify faulty
............
circuit if possible.
LAND as soon as practicable.