2.4. Parameter of the Unit
Model
MR550
MR650
MR750
Ambient Temperature: (DB/WB) 80.6°F/75.8°F; Water Inlet/Outlet
Temperature: 80°F.
1
Heating Capacity (kBtu/h) 52.9 62.07 73.36
1
Rated Input Power (kBtu/h) 8.814
9.68 12.52
1
COP 6.0
6.41 5.86
Ambient Temperature: (DB/WB) 50°F/44.3°F; Water Inlet Temperature: 80°F.
2
Heating Capacity (kBtu/h) 33.78
39.75 46.54
2
Rated Input Power (kBtu/h) 8.445
9.72 11.9
2
COP 4.0
4.09 3.91
Power supply(V/Ph/Hz) 208-230V~/ 60Hz
Ambient Temp Range F) 23~104
Maximum Water Outlet Temp. (°F) 104
Maximum Input Power (kBtu/h) 16.72 17.4 18.77
Maximum Running Current (A) 20 21.5 26.5
Maximum breaker (A) 30 30 40
Rated Water Flow (gpm) 23.07 27 31.48
Rated Water Pressure Drop (psi) 1.36 1.6 1.84
Refrigerant Quantity (lbs) R410A/3.417 R410A/4.85 R410A/4.41
Water Pipe Connection (inch) 1.5 1.5 1.5
Water Proof Class IPX4 IPX4 IPX4
Electricity Shock Proof Class
Sound Pressure at 1m dB(A) 56 57 58
Net Weight (lbs) 143 159 165
Net Dimensions W×D×H (inches) 39.4×15.7×26 45.3×17.9×30
Carton Dimensions W×D×H (inches) 42.1×16.3×26.8 47.8×19.31
The technical specification of our heat pumps is provided for information purposes only. We reserve
the right to make changes without notice.
Noise at 39.4 inches comply with Directives EN ISO 3741 and EN ISO 354
Calculations according to an in-ground private swimming pool covered with a solar blanket

Table of Contents