8A 8B
CODE
SET
SEL
CODE PED
LAMP/CORT
PGM.AUT
T.MOT
T.MOT.PED
T.PAUSA
IN.CMD.AP.
CODE
SET
SEL
CODE PED
LAMP/CORT
PGM.AUT
T.MOT
T.MOT.PED
T.PAUSA
IN.CMD.AP.
SET
SEL
T.MOT
T.MOT.PED
T.PAUSA
CODE
CODE PED
LAMP/CORT
PGM.AUT
IN.CMD.AP.
SET
SEL
T.MOT
T.MOT.PED
T.PAUSA
CODE
CODE PED
LAMP/CORT
PGM.AUT
IN.CMD.AP.
SET
SEL
T.MOT
T.MOT.PED
T.PAUSA
CODE
CODE PED
LAMP/CORT
PGM.AUT
IN.CMD.AP.
SET
SEL
T.MOT
T.MOT.PED
T.PAUSA
CODE
CODE PED
LAMP/CORT
PGM.AUT
IN.CMD.AP.
ENEN
The control board automatically sets a slowdown in opening and closing equal to
15% of the total course.
Aperture
85%
Normal speed
15%
slowdown
15%
slowdown
Closure
. PROGRAMMING
. PROGRAMMING
MAIN MENU MAIN MENU
• INB. CMD. AP | TRANSMITTER INHIBITION DURING THE OPENING AND PAUSE TIME • PGM. AUT. | COURSE AUTOMATIC PROGRAMMING
• LAMP/CORT | FLASHING LIGHT / COURTESY LIGHT SELECTION
With the function activated, the control board rejects all the transmitters and devices
signals during the opening maneuvers and automatic pause time.
The control board is supplied by the manufacturer with this function deactivated.
With the limit switches already set, the control board allows automatic programming of
the working time (recommended).
The control board has a 110V / 230V AC output for connection of a flashing light or
courtesy light at terminals 3 and 4 of CN1. This output does not flash. Observe the three
possible behaviors:
Enable OPTION 1:
With the LED lit, press SEL 4 or 5 times, and when the LED flashes (normally or quickly)
press the SET button and the LED turns off.
Enable OPTION 2:
With the LED LAMP / CORT off, press 4 times the SEL key until this LED blinks normally.
Press the SET button and the LED lights permanently.
Enable OPTION 3:
With the LED LAMP / CORT off, press 5 times the SEL key until this LED flashes quickly!
Press the SET button and the LED lights permanently.
01 • Press the SEL
button the times
necessary until the
INB CMD AP LED
starts to flash.
01 • Unlock the motor, put the gate halfway and lock the motor.
02 • Press the SEL
button the times
necessary until the
PGM AUT LED starts
to flash.
02 • Press SET button
to enable / disable
the function.
03 • Press and hold
SET and the door
must begin to close!
Activate (LED ON) / deactivate (LED OFF) function:
Enable automatic programming:
Automatic slowdown:
If the gate start to open, release the SET button, reverse the wires of links 5 and
7 of CN1, and start this program from the beginning.
04 • Allow the gate
to close, open and
close again without
releasing the SET
button!
05 • When closing the
2nd time, the PGM
AUTO LED will be lit
and the programming
has been successfully
completed.
1
2
OPTIONS
BEHAVIOR
(factory)
Opening Pause Time Closing 3min. After Closing
3min. After Closing
3min. After Closing
Opening Pause Time Closing
3
Opening Pause Time Closing