01
03. CONFIGURATION 03. CONFIGURATION
EXTENDED MENU 2
EXTENDED MENU 2
The electronic lock in pedestrian function is used when there is, for example, a swing
doors assembled with electric lock to close the door 2. This makes it possible to
obtain the opening of the gate by trigger a push-button connected in PUL, PED or to
trigger the remote control.
The transmitter is supplied by the manufacturer with the electronic lock on the pe-
destrian function disabled.
Activate (LED ON)/deactivate (LED OFF) function:
01. Enter the extended menu 2.
02. Press SEL button as often as necessary until the T. MOT. LED start to flash.
03. Press once SET button to enable / disable the function.
The T. MOT. LED ON indicates that the function is activated and the T. MOT. LED OFF
signals that the function is disabled.
The control board permits that the PUL input work with a push button (NA) exclusi
-
vely for opening and PED input work with a push button (NA) only for closing.
The control board is supplied by the manufacturer with the operation of the PUL
input for connection to a primary push-button (NA) cyclic and PED input for connec-
ting a pedestrian pushbutton (NA) cyclic.
• T. MOT. | ELECTRONIC LOCK IN PEDESTRIAN FUNCTION
• T. MOT. PED | OPERATIONS THE INPUTS PUL AND PED
EXTENDED MENU 3
LEVEL OF THE POWER LEDS ON
1 AUT/P-P.
2 AUT/P-P. • CODE
3 AUT/P-P. • CODE • CODE PED
4 AUT/P-P. • CODE • CODE PED • INB. CMD. AP
5 AUT/P-P. • CODE • CODE PED • INB. CMD. AP • T. MOT.
6 AUT/P-P. • CODE • CODE PED • INB. CMD. AP • T. MOT. • T. MOT. PED
With the extended menu 3 can program the power / motor speed at which will be per-
formed the deceleration.
To access the Extended menu 3 options proceed as follows:
01. Enter the extended menu 1 (see page 06.B).
02. Enter the extended menu 2 (see page 08.A).
03. Continuously press the SET button for 5 seconds and the T.PAUSA and T. RIT. ANTE
LEDs will flash alternately for a few moments and flash simultaneously afterwards.
04. You have 30 seconds to select from the extended menu 3 functions (using the SEL
and SET button), and after this time the control board returns to the main menu.
EXTENDED MENU 3
PUL= opening, PED= closing (LED ON) / PUL=PUL and PED=PED (LED OFF):
01. Enter the extended menu 2.
02. Press SEL button as often as necessary until the LED T. MOT. PED starts to flash.
03. Press once SET button to change the function.
The T. MOT. PED LED ON signals that the PUL is programmed for opening and PED for
closing. The T. MOT. PED LED OFF indicates that the function PUL is programmed to
function with a main cyclic push-button (NO) and the PED input to connect a pedes-
trian cyclic push-button (NO).
With function "Soft Start" enabled, the beginning of each movement, the control board
will control start the motor, increasing power gradually in the first 2 seconds of opera-
tion.
The control board is supplied by the manufacturer with the "Soft Start" disabled.
Activate (LED ON) / deactivate (LED OFF) function:
01. Enter the extended menu 2.
02. Press SEL button as often as necessary until the LED INB. CMD. AP. starts to flash.
03. Press once SET button to enable / disable the function.
The INB. CMD. AP. LED ON indicates that the function is activated and the INB. CMD. AP.
LED OFF signals that the function is disabled.
• INB. CMD. AP. | SOFT START