Table
22-1
. IEEE-488 Interface Controllable Functions
Control/Measurement Comment
Function
Switch
Generat
e/ Power Monit
or
/
Monit
or
Modullllon
Control
Co
nt
i
nu
ou
s/O
FF
/BURST
Wldeband/
Narrowband
Switch
Image
High
/
Low
Switch
Duplex
Oscillator
Switch
0- 10
MH
z/O
FF
/45
MH
Z
Keyboard Numeric Entri
es
0-9.
Can be transmi
tt
ed to the
bus.
Display Mode
Generate
/ Monitor
Meteri
ng
(N ote: 1)
Mo
dula
ti
on
Sp
ec
trum Analyzer
Dup
lex
Genera
tor
AF
Memo
ry
T
one
Memo
ry
Frequen
cy
Coun
ter
DVM
E
xterna
l
Watl
m
eter
IF
Scope AC
Scope DC
Remo
te Terminal M
ode
Unit can also disp
la
y a subset
of
ASC
II
characte
rs
(numerals
0-9, upper c
as
e alpha letters
A-Z, plus
oth
er symbols- ASCI I
characters
20
thru 5F H
ex
a-
decimal)
enables display of
operator messages on C
RT
display in a transparent ter-
m
i~
al
mode.
Function
Mode
FM
(Note: 1)
cw
AM
SSB/ DSB
SWP 1-10
MHz
SWP 0.01-1 MHz
Code
Synthesizer
Mode
PL/ OPL
PL/
DP
L Inve
rt
Tone
A
Tone
B
A/ 8
T
one
Remo
te
Control/ Measurement Comment
1-
_______
::_:PL:_..:,Fr~eq.:!u::;•:::":::rcy
Fr
equency
en
try
to be
RF
Fre<>uencvl
OPL
Code
supp
lied
~Y
prog
r
a~
j...:....-------.....!:~~~
Fr
equenc
1e
s
no
t available
1------,:,T:::onc:.:•:..:A,:...:,Fr:.:•.:.qu:::•::.n:.::!.cy
from
memory
table.
Tone
B
Frequency
Time
Sequence Select Seq uences 1 t
hr
ough
5
on
ly (Not
e:
2)
Wattmeter
Element
Select
External
Modulation
M
od
ulation settable to a
ny
mea
su
rable
le
vel
Code
Synthesizer
Modulation
(0-20 KHz deviat
ion
in
10 Hz
steps) (Note:
3)
(0-90% AM in 0.1% steps)
RF
level RF level settable
to
any
displayab
le level (-1 40
to
+ 11 d
Bm
in 0.1 d Bm steps
(
No
te: 3)
(Note
: 4)
Of1set
Osc
i
llator
Adjust
Duplex
Generato
r Freq
uency
Settable from
fa
to
fo
±10
MHz in 1 KHz steps (
Switch)
placed in 0
-1
0
MHz
position)
(Nole: 3)
Scope Vertical Step
Attenuator
0.0 1, 0.1,
1,
10 volts
Horizontal
Scope Sweep 1, 10, 1
00
millisec
on
ds
1. 10, 100 mic
rosecond
s
External
lnpu1
Power
Meier)
Frequency
Error
Deviation +
or
-
%'
AM
.,.
or
-
External Fr
equency
Count
External
Power
Meter
FWD
/REV
Notes: (1) May
be
a
ll
ected
by
other con
tr
ols (see bel
ow)
.
(2) Sequence 5 t
im
i
ng
is
prog
rammable
under
IEEE bus cont
ro
l
(3) As reading is displayed, LED
cor
responding to appropriate
display and
functio
n mode will illuminate.
(4) T
he
IEEE-Bus option. due to a change in the
RF
step attenuator,
restricts the maxi
mum
RF
out
put
to
.,.1
1 dBm.
NON-CONTROLLABLE FUNCTIONS
Since
control
and
monitor
functions
of
the inter-
face are
implemented
to
obtain remote measure-
ment
capability
, certain
front
panel controls are
not
implemented in the interface due to
their
local operator orientation. A list
of
these oper-
ator oriented
controls are
as
follows:
Power On/
011
Power Mode Indicators
Display
Focus
Display Intensity
Dispersion/Sweep
Scope/DVM Vertical Vernier
Scope
Trigger
Level
Scope
Trigger
Slope
Scope Horizontal Sweep Vernier
Scope Vertical
Position
Scope
Horizontal Position
Receiver
Squelch
Receiver Volume
Zero
Beat
Indicator
RF
Scan
RF
Memory Table
Tone Sequences.
6,
7,
and 8
Entries
22-2
Deviation Lim it
Battery
Voltage Reading
De
viation
Limit
Alarm (Disabled
Under
Rem
ote Control)
Attenuator 0 Indicator
Battery Below
Limit
Warning
BFO Frequency Adjust
8521·66