3.10.0
TWO-WAY
SERVICE
OPTION
OPERATING
SYSTEM
Being
the first in a series, the Two-Way Service Option
card
is structured with a unique
operating
system which
uses a list
of
numeric commands to accommodate the nu-
merous signalling variables found in the land mobile in-
dustry signalling standards. This operating system requires
the
operator
to first select the
OPTION
position within
the
code
synthesizer
section
of
the R-2200. The follow-
ing
paragraphs
detail
how
the
operator
accesses
these
unique functions.
The functions
of
the R-2200 provided by the Two-Way
Service Option, RTL-4161A, are accessed via a special set
of
Function Codes. Each mode
of
operation has a unique
code which must be entered by the operator. These Func-
tion Codes are listed below.
OPTION
CODE
I l
l 2
2 l
3 l
3 2
FUNCTION
DPL
Decode
Inverted
DPL Decode
DTMF Decode
DTMF Batch Encode
Timing-
Tone
Duration and Delay
(Default
= 100 ms
on,
50 ms off)
PL Frequency Select for simul PL and
DTMF Encode
3 3 DTMF Manual Encode without PL
3 4 DTMF Batch Encode without PL
3 5 DTMF Manual Encode with PL
3 6 DTMF Batch Encode with PL
3.10.1
DPL/IDPL
DECODE
This sequence is for any DPL (DIGITAL PRIVATE LINE)
or
Inverted
DPL
(IDPL) decoding. The
DPL
or
IDPL
modes
of
operation
are accessed by first selecting the
OPTION
position
of
the code synthesizer.
3.10.1.1
DPL
DECODE-ACCESS
CODE
11
Press
Press
Numeric
Program
Key
Key
Display
Comment
4 1 Current state
of
NV
memory.
dPL - - - Ready to decode DPL
NOTE:
Shaded
area
indicates
flashing
digit.
(point
of
data
entry)
3.10.1.2
IDPL
DECODE-ACCESS
CODE
1 2
Press
Press
Numeric
Program
Key
Key
Display
Comment
4 1
Current
state
of
NV
memory.
1 2
, ..... , dPL - - - Ready to decode
IDPL
NOTE:
Shaded
area
indicates
flashing
digit.
(point
of
data
entry)
3.10.2
DTMF
DECODE
This sequence allows decoding
of
the standard
16
DTMF
tone pairs. Decoding
of
DTMF tone pairs
is
functional from
3 different sources. The decoder will function
OFF-THE
AIR, with a direct radio connection
or
from the External
Modulation In BNC connector (EXT
MOD), located in the
Modulation
Section
of
the R-2200 front panel. The Func-
tion
Switch must be
in
the
"Gen"
or
"Hi
Gen"
position to
decode
DTMF
tones via the External Modulation BNC
connector. DTMF decoding modes
of
operation include a
BATCH
DECODE mode. When a series
of
DTMF digits
must be decoded, a maximum
of
16
digits can be decoded
and stored in memory.
3.10.2.1
DTMF
BATCH
DECODE-ACCESS
CODE
2 1
Press Press
Numeric
Program
Key Key
Display
Comment
'31 Current state
of
NV
memory.
2
EJ
dFd---
Place MODULATION
SWITCH
in
"CONT"
and the unit is ready to
decode
DTMF
Decode
DTMF
while
Modulation
Switch is in
"CONT"
position.
When finished decoding
DTMF
tone pairs, place
Modulation
Switch in
"OFF"
position.
~
dFd 123
Using right cursor, review
code stored in NV
memory.
~
=1234
"dFd"
has now scrolled
off
the LCD display.
~
=12345
Scrolling through
memory
~
1234567
A total
of
7 digits
maximum can be
displayed at a single time.
~
234567=
End
of
decoded sequence
is now reached.
@JorEJ
1234567
Backspace using left
cursor
or
press Reset.
dFd---
Place MODULATION
SWITCH
in
CONT
to
clear
display
and
ready
for
another
decoding
sequence.
NOTE:
Shaded
area
indicates
flashing
digit.
(point
of
data
entry)
3-12