EasyManua.ls Logo

MPP Solar 3KVA - Specifications; Table 1 Line Mode Specifications

MPP Solar 3KVA
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
SPECIFICATIONS
Table 1 Line Mode Specifications
INVERTER MODEL
3KVA
Input Voltage Waveform
Sinusoidal (utility or generator)
Nominal Input Voltage
120Vac
Low Loss Voltage
95Vac± 3% (UPS)
85Vac± 3% (Appliances)
Low Loss Return Voltage
100Vac± 3% (UPS);
90Vac± 3% (Appliances)
Boost activation voltage
108Vac± 3%
Boost deactivation voltage
111Vac± 3%
Buck activation voltage
132Vac± 3%
Buck deactivation voltage
129Vac± 3%
High Loss Voltage
140Vac± 3%
High Loss Return Voltage
135Vac± 3%
Max AC Input Voltage
150Vac
Nominal Input Frequency
50Hz / 60Hz (Auto detection)
Low Loss Frequency
40± 1Hz
Low Loss Return Frequency
42± 1Hz
High Loss Frequency
65± 1Hz
High Loss Return Frequency
63± 1Hz
Output Short Circuit Protection
Line mode: Circuit Breaker
Battery mode: Electronic Circuits
Efficiency (Line Mode)
>95% ( Rated R load, battery full charged )
Transfer Time
*
10ms typical, 12ms maximum @50Hz (UPS);
20ms typical, 25ms maximum @50Hz (Appliances)
Output power derating:
When AC input voltage drops to 95V
depending on models, the output power
will be derated.
Output Power
Rated Power
50% Power
Input Voltage
85V 95V 140V