SPECIFICATIONS
Table 1 Line Mode Specifications
INVERTER MODEL
3KVA
Input Voltage Waveform
Sinusoidal (utility or generator)
Nominal Input Voltage
120Vac
Low Loss Voltage
95Va 3% (UPS)
85Va 3% (Appliances)
Low Loss Return Voltage
100Vac± 3% (UPS);
90Vac± 3% (Appliances)
Boost activation voltage
108Va 3%
Boost deactivation voltage
111Va 3%
Buck activation voltage
132Va 3%
Buck deactivation voltage
129Va 3%
High Loss Voltage
140Va 3%
High Loss Return Voltage
135Va 3%
Max AC Input Voltage
150Vac
Nominal Input Frequency
50Hz / 60Hz (Auto detection)
Low Loss Frequency
40± 1Hz
Low Loss Return Frequency
42± 1Hz
High Loss Frequency
65± 1Hz
High Loss Return Frequency
63± 1Hz
Output Short Circuit Protection
Line mode: Circuit Breaker
Battery mode: Electronic Circuits
Efficiency (Line Mode)
>95% ( Rated R load, battery full charged )
Transfer Time
*
10ms typical, 12ms maximum @50Hz (UPS);
20ms typical, 25ms maximum @50Hz (Appliances)
Output power derating:
When AC input voltage drops to 95V
depending on models, the output power
will be derated.
Output Power
Rated Power
50% Power
Input Voltage
85V 95V 140V