22
30
Battery equalization
Battery equalization
Battery equalization disable
(default)
If “Flooded” or “User-Defined” is selected in program 05, this
program can be set up.
31
Battery equalization voltage
default: 58.4V
Setting range is from 48.0V to
62.0V. Increment of each click is
0.1V.
33
Battery equalized time
60min (default)
Setting range is from 5min to
900min. Increment of each click
is 5min.
34
Battery equalized timeout
120min (default)
Setting range is from 5min to 900
min. Increment of each click is 5
min.
35
Equalization interval
30days (default)
Setting range is from 0 to 90
days. Increment of each click is 1
day
36
Equalization activated
immediately
Enable
Disable (default)
If equalization function is enabled in program 30, this program
can be set up. If “Enable” is selected in this program, its to
activate battery equalization immediately and LCD main page will
show “ . If “Disable” is selected, it will cancel equalization
function until next activated equalization time arrives based on
program 35 setting. At this time, “ ” will not be shown in LCD
main page.