61/65/70/75 Series Horizontal Shaft Engines
84
6. Connect one lead of the multimeter to the blue wire
that goes to the remote switch.
7. Connect the other lead of the multimeter to a good
ground. Blue wire Continuity
8. Set the multimeter to the ohms () scale.
If the multimeter shows continuity, Check the
black wire from the module for an open or
replace the module. See Figure 7.8.
If the multimeter does not show continuity,
check the wire for a break and check the
ground connection. See Figure 7.9.
Figure 7.8
Blue wire
Continuity
Figure 7.9
Blue wire
Ground connection