Chapter 6: Starters
64
6. Connect the ground lead to the ground side of a
12V power source. See Figure 6.16.
7. Connect the positive side of the power source to
the terminal that has the piggy back wire on it.
See Figure 6.17.
8. Reconnect the DMM with it still on the Ohms (Ω)
scale. See Figure 6.18.
NOTE: The DMM should read less than 0.2
Ohms (Ω). This relay has a burnt contact.
9. If the test results do not match what was listed
above, replace the relay.
Figure 6.16
Ground lead
Ground side
of power source
Figure 6.17
Piggy back wire
Figure 6.18
www.mymowerparts.com