11
Temposonics
®
 GTE Analog ATEX / NEC / CEC
Operation Manual
5.3 Safety screw
A M5×10 set screw to ISO 4026 with flat point should be used. This 
safety screw is only required for blocking the sensor housing in axial 
direction and needs to butt only against the groove, i.e. the screw 
may be tightened only with a torque of 0.5 Nm to prevent damaging 
the sensor. The set screw should be inserted with a resolvable safety 
adhesive, e.g. Loctite blue.
Set screw
e.g. retaining with set screw ISO 4026 M5×10 (with at point!).
Fastening torque: 0.44 Nm to 0.50 Nm
Notice: Ensure threads are free of oil, grease and debris
4.5
(0.18)
45°
4.5
(0.18)
43.8
(1.72)
1
(0.04)
Fig. 6: Set screw for GTE sensor
6.  Inspection, maintenance, others
6.1 Assembly, disassembly
During assembly and disassembly, it is important to follow best prac-
tices for working with electronic components.
Before using the device, please ensure the following:
•  The device is installed according to the local and national 
regulations.
•  The requirements for the applicable explosion category  
were taken into account.
•  The device is not damaged.
•  The installation location is clean.
6.2 Inspection and maintenance
Follow the denitions and regulations according to IEC 60079-17.
Annual inspection should be conducted for the housing that contains 
the embedded sensor to ensure proper grounding.
6.3 Fault clearance
No modications of the sensors are allowed.
6.4 Disposal
The disposal of the packaging materials and used parts has to take 
place according to the regulations of the country in which the device is 
installed.
NOTICE
The safety screw must be sealed to prevent moisture or liquid from 
passing through during the cylinder production or later when the 
machine is operating!
Controlling design dimensions are in millimeters and measurements in ( ) are in inches