2.4 Safety instructions for use in explosion-hazardous areas
The sensor has been designed for operation inside explosion-hazarded 
areas. It has been tested and left the factory in a condition in which 
it is safe to operate. Relevant regulations and standards have been 
observed. According to the marking (ATEX and NEC/CEC) the sensor 
is approved only for operation in dened hazardous areas (see chapter 
“2.1 Intended use” on page 3 and table in chapter 8).
2.5 Warranty
MTS Sensors grants a warranty period for the Temposonics
®
position sensors and supplied accessories relating to material
defects and faults that occur despite correct use in accordance with
the intended application 
2
. The MTS Sensors obligation is limited to
repair or replacement of any defective part of the unit. No warranty
can be provided for defects that are due to improper use or above
average stress of the product, as well as for wear parts. Under no
circumstances will MTS Sensors accept liability in the event of offense
against the warranty rules, no matter if these have been assured or
expected, even in case of fault or negligence of the company.
MTS Sensors explicitly excludes any further warranties. Neither
the company’s representatives, agents, dealers nor employees are
authorized to increase or change the scope of warranty.
2.6 Return
For diagnostic purposes, the sensor can be returned to MTS Sensors 
or a repair facility explicitly authorized by MTS Sensors. Any shipment 
cost is the responsibility of the sender 
2
. For a corresponding form, see 
chapter “10. Appendix” on page 14.
2/  See also applicable MTS Sensors terms of sales and delivery on: www.mtssensors.com
NOTICE
When returning sensors, place protective caps on male and female 
connectors of the sensor. For pigtail cables, place the cable ends in 
a static shielding bag for electrostatic discharge (ESD) protection. 
Fill the outer packaging around the sensor completely to prevent 
damage during transport.
 16. Make sure that:
• the sensor and associated components were installed   
according to the instructions
• the sensor enclosure is clean
• the magnet does not grind on the rod. This could cause damage 
to the magnet and the sensor rod. If there is contact between the 
moving magnet (including the magnet holder) and the sensor 
rod, make sure that the maximum speed of the moving magnet 
is less or equal 1 m/s.
 17. Grounding of the system (sensor + cylinder) to the local earth  
has to be done at the metallic cylinder. To ensure proper  
electrical grounding, the connection between the sensor housing  
and the metallic cylinder (or housing) must be ensured by  
fasteners (e.g., screws).
 18. Before applying power, ensure that nobody’s safety is    
jeopardized by starting machines.
 19. Check the function of the sensor regularly and provide    
documentation of the checks        
(see chapter “6.2 Inspection and Maintenance” on page 10).