9
Temposonics
®
 GTE Analog ATEX / NEC / CEC
Operation Manual
4.2 Styles and installation of Temposonics
®
 GTE
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
GTE Analog ATEX / NEC / CEC
Magnet
3.4
(0.13)
TPV cable,
part no. 530 162
bending radius: 5 × D
13
(0.51)
37.5
(1.48)
50…2540
(2…100)
63.5
(2.5)
4
(0.16)
Ø 25
(Ø 1)
Ø 48
(Ø 0.19)
Ø 10
Ø 60 f7
(Ø 2.36 f7)
19.2
4.5
(0.18)
Ø 60 f7
(Ø 2.36 f7)
28
(1.1)
20.3 (0.8)
14 (0.55)
Sensor electronics housing
56.8
(2.24)
Fig. 3: Temposonics
®
 GTE with ring magnet
4.3 Electrical connection
Connector wiring
Connect the sensor directly to the control system, indicator or other 
evaluating systems as follows:
Fig. 4: Connector wiring: 6-wire shielded cable
BXX 
Signal + power supply
Cable Color Function
GY Position
PK Return for output
YE Programming (RS-485 +)
GN Programming (RS-485 −)
BN Supply voltage
WH DC Ground (0 V)
Shield Only connected on controller side