7
Temposonics
®
 GTE Analog ATEX / NEC / CEC
Operation Manual
3.2 Nameplate
3.3 Approvals
See chapter “7. Technical data Temposonics
®
 GTE Analog ATEX / 
NEC / CEC”, chapter “8. Certications” and chapter “9. Declaration of 
conformity of GTE Analog” on page 12 – 13.
  Class I Zone 2 AEx/Ex nA IIC T4 Gc
  Class II/III Zone 22 AEx tc/Ex tc IIC T130 °C Dc
LR1346-4  Class I/II/III Div 2 T4 ABCDEFG
 
 II 3G Ex nA IIC T4 Gc
  IECEx BVS 13.0063X
  –20 °C ≤ +75 °C (–4 °F ≤ +167 °F)
3.4 Scope of delivery
GTE (rod sensor):
•  Sensor
•  O-ring
•  Back-up ring
Fig. 1: Example of a nameplate of a GTE sensor
Class I Zone 2 AEx/Ex nA IIC T4 Gc
Class II/III Zone 22 AEx tc/Ex tc IIC T130°C Dc
Class I/II/III Div 2 T4 ABCDEFG
II 3G Ex nA IIC T4 Gc
IECEx BVS 13.0063X
–20 °C ≤ T amb ≤ ±75 °C
LR1346-4
1725
IP64
USA: Tel. +1 800-633-7609
Germany: Tel. +49 2351-95870
GTE0105MB011A0-EX
S/N: 9048532
In: 24 VDC
Out: 4-20 mA
Sensor model
Stroke length (e.g. 105 mm)
Connection type
Part no.
Output