Reference Temperature (Only if 6C MOD is selected)
Select the desired base temperature for the volume calculations. The allowable values are
32°F to 150°F.
If you wish to change the reference temperature, enter the new value and press the
ENTER key.
Custom Table Entry (Only if CUST TAB is selected)
The custom table function allows the user to create a custom data table that defines the
temperature expansion characteristics of the product being measured. This function can
be used when the expansion characteristics of the product do not follow API tables 6A,
6B or 6C.
Press the mode key to begin editing the custom VCF table, or press ENTER to continue to
TANK DENSITY. The number of entries for tank #1 VCF table is shown. If you wish to
change this number press the mode key.
Use the number keys to change the number of entries for tank #1 VCF table and press
the ENTER key. Table sizes can range from 2 to 50 entries.
TANK #1 VCF TABLE
SIZE 10
‘Mode’ TO CHANGE
‘Enter’ TO CONTINUE
TANK #1 CUSTOM VCF
TABLE
‘Mode’ TO CHANGE
‘Enter’ TO CONTINUE
NOTE
Refer to Appendix A for additional information about
creating custom volume expansion tables.
TANK #1 REF. TEMP.
----- °F
‘Enter’ NEW VALUE
TANK #1 REF. TEMP.
60.0 °F
‘Mode’ TO CHANGE
‘Enter’ TO CONTINUE
56