10. Analog Output Module/ Wiring Procedures
This section describes wiring procedures for analog systems that use the Analog Output Module, including:
• 0 to 10 V displacement (forward and reverse acting)
• -10 to +10 V displacement (forward and reverse acting)
• Ungrounded 4 to 20 mA displacement
• Grounded 4 to 20 mA displacement
• Velocity Outputs
• Dual Channel Outputs
Connections are made between the transducer assembly, the AOM, the customer-supplied power supply, and the
customer-supplied receiving device.
10.1 Preparing Cable for Connection to the AOM
The AOM is equipped with two strain relief or two MS (mil-spec) connectors.
A strain relief is used for an un-terminated cable. Prepare the cable as shown in Figure 10-1. It is recom-
mended that you tin the exposed leads to ensure a good connection. Mount the cable to the AOM, ready
to make connections to the terminal boards (TB1, TB2, or TB3) inside.
Figure 10-1
Cable Preparation for Strain Relief
When the AOM box is used an optional MS connector can be used with the cable. Cables are available in
various lengths from inventory.
Strain Relief
Split Ring Cable Clamp
Cable Seal
Male Threaded Nipple
(Do not remove)
AOM Enclosure
1 in.0.25 in. 3 in.