12. Analog Output Card
The Analog Output Card is a plug-in type electronics card that performs the same functions as the Analog Output
Module (AOM) and can be used as a direct replacement (physically and functionally) for the "old style"
Temposonics Electronics Card.
Figure 12-1
Analog Output Card Dimensions
The displacement output options available from the Analog Output Cards are as follows:
Voltage Outputs:
• 0 to 10 Vdc (forward and reverse acting)
• 0 to -10 Vdc (forward and reverse acting)
• -10 to +10 Vdc (forward and reverse acting)
Current Outputs:
• 4 to 20 mA ungrounded (forward and reverse acting)
• 4 to 20 mA grounded (forward and reverse acting)
Null (R20) and scale (R24) adjustments are available on the Analog Output Card.
Null Adjustment:
Using a digital voltmeter, turn potentiometer (R20) to increase or decrease the voltage output until null is
set at 0.000 Vdc.
Scale Adjustment:
Using a digital voltmeter, turn potentiometer (R24) to increase or decrease the voltage output until full
scale output is set at 10.000 Vdc.
4.5 in.
3.8 in.
5.0 in.
0.375 in.
2.484 in.
1.008 in.
5.375 in.
0.187 in.
R20
R24
36