12. Analog Output Card
The Analog Output Card is a plug-in type electronics card that performs the same functions as the Analog Output
Module (AOM) and can be used as a direct replacement (physically and functionally) for the "old style"
Temposonics Electronics Card.
Figure 12-1
Analog Output Card Dimensions
The displacement output options available from the Analog Output Cards are as follows:
Voltage Outputs:
• 0 to 10 Vdc (forward and reverse acting)
• 0 to -10 Vdc (forward and reverse acting)
• -10 to +10 Vdc (forward and reverse acting)
Current Outputs:
• 4 to 20 mA ungrounded (forward and reverse acting)
• 4 to 20 mA grounded (forward and reverse acting)
Null (R20) and scale (R24) adjustments are available on the Analog Output Card.
Null Adjustment:
Using a digital voltmeter, turn potentiometer (R20) to increase or decrease the voltage output until null is
set at 0.000 Vdc.
Scale Adjustment:
Using a digital voltmeter, turn potentiometer (R24) to increase or decrease the voltage output until full
scale output is set at 10.000 Vdc.