Table 10K Retrofit Connections -
Temposonics II Replacement of Existing Temposonics I with AOM
Temposonics II Integrated or Extension Cable (Notes 1, 2) Analog Output Module (AOM)
Pin No. Wire Color Code Wire Color Code Functional Description Terminal Blocks Military Style (MS)
Connectors
1 White/Blue Stripe White DC Ground TB2-B J2 Pin B
2 Blue/White Stripe Brown Frame (Note 3) TB2-B J2 Pin B
3 White/Orange Stripe Gray Not Used Not Used Not Used
4 Orange/White Stripe Pink Not Used Not Used Not Used
5 White/Green Stripe Red +Vdc TB2-F (Note 4) J2 Pin F (Note 4)
6 Green/White Stripe Blue -Vdc TB2-D J2 Pin D
7 White/Brown Stripe Black Return (GND) TB2-B J2 Pin B
8 Brown/White Stripe Violet Output (return pulse) TB2-C J2 Pin C
9 White/Gray Stripe Yellow (+) Interrogation (Note 5) TB2-E J2 Pin E
(See warning, below)
10 Gray/White Stripe Green (-) Interrogation (Note 6) TB2-B J2 Pin B
(See warning, below)
NOTES:
1. Verify if the cable has striped or solid color leads and make connections accordingly.
2. Cable: Belden #8105 or equivalent
3. Frame ground is isolated from circuit ground inside the electronics enclosure or head of the transducer.
4. Connect to TB2 Pin A if the stoke length exceeds 180 inches.
5. For retrofitting AOMs with stoke lengths greater than 12 inches in stroke length and positive (+) interrogation.
6. For retrofitting AOMs with stoke lengths greater than 12 inches in stroke length and negative (-) interrogation.
7. Shield: Connect extension cable shield at TB2-B or J2 Pin B.
!WARNING!
Under no condition connect both the
positive (+) and negative (-) interroga-
tion wires to TB2-E at the same time. The
unused interrogation lead MUST be
connected to DC Ground.