MODEL RELATED DATA (basic design)
Number of cylinders 12 16
Number of cylinders 12 16
Cylinder arrangement: V angle Degrees
(°)
90 90
Bore mm 135 135
Stroke mm 156 156
Cylinder displacement Liters 2.233 2.233
Total displacement Liters 26.80 35.73
Inlet valves per cylinder 2 2
Exhaust valves per cylinder 2 2
COMBUSTION AIR / EXHAUST GAS
Number of cylinders 12 16
Charge-air pressure before cylinder R bar abs 3.95 3.80
Exhaust temperature after turbocharger R °C 390 390
COOLANT SYSTEM (HT circuit)
Number of cylinders 12 16
Coolant temperature (at engine connection: outlet to cooling
equipment)
A °C 100 100
Coolant temperature after engine, warning R °C 101 101
Coolant temperature after engine, shutdown L °C 104 104
Coolant antifreeze content, max. L % 50 50
Coolant pump: inlet pressure, max. L bar 1.3 1.3
Thermostat: Starts to open R °C 79 79
Thermostat: Fully open R °C 92 92
COOLING SYSTEM (LT circuit)
Number of cylinders 12 16
Coolant antifreeze content, max. L % 50 50
Charge-air temperature after charge-air cooler, max. L °C 95 95
Thermostat: Starts to open R °C 38 38
Thermostat: Fully open R °C 51 51
LUBE OIL SYSTEM
Number of cylinders 12 16
Lube oil operating temperature before engine, from R °C 80 80
Lube oil operating temperature before engine, to R °C 103 103
Lube oil temperature before engine, alarm R °C 103 103
Lube oil temperature before engine, shutdown L °C 106 106
Lube oil operating pressure before engine, warning R bar 6.0 6.0
Lube oil operating pressure before engine, shutdown L bar 5.5 5.5