General conditions (for maximum power)
ID 1 2 3
Intake depression (new filter) A mbar 15 15 15
Intake depression, max. L mbar 30 30 30
Exhaust gas overpressure, max. L mbar 85 85 85
Fuel temperature at engine supply connection, max. L °C 50 50 50
Model related data (basic design)
ID 1 2 3
Cylinder arrangement: V-angle Degrees
(°)
90 90 90
Bore mm 135 135 135
Stroke mm 156 156 156
Displacement, cylinder Liters 2.23 2.23 2.23
Displacement, total Liters 26.76 26.76 26.76
Number of inlet valves per cylinder - 2 2 2
Number of exhaust valves per cylinder - 2 2 2
Raw water circuit (open circuit)
ID 1 2 3
Raw water: Pressure in raw water system, max. L bar 4.0 4.0 4.0
Raw water pump: Inlet pressure, min. L bar -0.4 -0.4 -0.4
Lube oil system
ID 1 2 3
Lube-oil operating temperature before engine, from R °C 75 75 75
Lube oil operating temperature before engine, to R °C 88 88 88
Lube oil operating pressure upstream of engine, from R bar 7.0 7.0 7.0
Lube-oil operating pressure before engine, to R bar 8.0 8.0 8.0
Lube oil operating pressure (low idle) (meas. point:
before engine)
R bar 3.5 3.5 3.5
Fuel system
ID 1 2 3
Fuel pressure at engine inlet connection, min. (when
engine is running)
L bar -0.5 -0.5 -0.5
Fuel pressure at engine inlet connection, max. (when
engine is starting)
L bar 0.5 0.5 0.5
General operating data
ID 1 2 3
Firing speed, from R rpm 100 100 100
Firing speed. to R rpm 120 120 120
MS150119/01E 2016-02 | Technical Data | 45