Number of cylinders 16
Number of inlet valves, per cylinder 2
Number of exhaust valves, per cylinder 2
RAW WATER CIRCUIT (open circuit)
Number of cylinders 16
Raw water pump: inlet pressure, min. L bar -0.3
Raw water pump: inlet pressure, max. L bar +0.5
Pressure loss in the external raw water system, max. L bar 0.7
LUBE OIL SYSTEM
Number of cylinders 16
Lube oil operating temperature before engine, from R °C 84
Lube oil operating temperature before engine, to R °C 89
Lube oil operating pressure before engine, from R bar 6.4
Lube oil operating pressure before engine, to R bar 7.4
Lube oil operating pressure, low idle (meas. point: before engine) R bar 3.0
FUEL SYSTEM
Number of cylinders 16
Fuel pressure at supply connection to engine (when engine is starting), min. L bar -0.3
Fuel pressure at supply connection to engine (when engine is running),
min.
L bar -0.3
Fuel pressure at supply connection to engine (when engine is starting),
max.
L bar +0.5
Fuel supply flow, max. R liter/min 4.5
GENERAL OPERATING DATA
Number of cylinders 16
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 16
Rated starter voltage (standard design) R V= 24
STARTING (pneumatic starter)
Number of cylinders 16
Starting air pressure before starter motor, min. R bar 24
Starting air pressure before starter motor, max. R bar 30