(I) Unit Engine-mounted heat
exchanger
Remote heat ex-
changer
Oil pan at dipstick mark “min.” (standard
oil system) (Option: max. operating incli-
nations)
L Liters 100 100 100 100
Oil pan at dipstick mark “max.” (standard
oil system) (Option: max. operating incli-
nations)
L Liters 130 130 130 130
Weights / main dimensions
(I) Unit Engine-mounted heat
exchanger
Remote heat ex-
changer
Engine dry weight (with standard acces-
sories installed, w/o coupling)
R kg 6085 6085 5680 5680
Noise
(I) Unit Engine-mounted heat
exchanger
Remote heat ex-
changer
Exhaust noise, unsilenced – BL (free-field
sound-pressure level Lp, 1 m distance,
ISO 6798, +3 dB(A) tolerance)
R dB(A) 109 109 109 109
Engine surface noise with attenuated in-
take noise (filter) – BL (free-field sound-
pressure level Lp, 1 m distance, ISO
6798, +2 dB(A) tolerance)
R dB(A) 104 104 104 104
60 | Technical Data | MS150109/01E 2015-11
TIM-ID: 0000045044 - 001