3.3 Engine data 8V4000M54R, Marine EPA Tier 3, IMO Tier II
Explanation
Index (I) Meaning
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Reference conditions
(I) Unit Engine-mounted heat
exchanger
Remote heat ex-
changer
Application group 1A 1A 1A 1A
Intake air temperature °C 25 45 25 45
Raw water inlet temperature °C 25 32 25 32
Barometric pressure mbar 1000 1000 1000 1000
Site altitude above sea level m 100 100 100 100
Power-related data (power ratings are net brake power as per ISO 3046)
(I) Unit Engine-mounted heat
exchanger
Remote heat ex-
changer
Rated engine speed A rpm 1600 1600 1600 1600
Fuel stop power ISO 3046 A kW 746 746 746 746
General conditions (for maximum power)
(I) Unit Engine-mounted heat
exchanger
Remote heat ex-
changer
Intake depression (new filter) A mbar 15 15 15 15
Intake depression, max. L mbar 30 30 30 30
Exhaust gas overpressure A mbar 30 30 30 30
Exhaust gas overpressure, max. L mbar 85 85 85 85
Fuel temperature at engine inlet connec-
tion
R °C 25 25 25 25
Fuel temperature at engine inlet connec-
tion, max.
L °C 55 55 55 55
MS150109/01E 2015-11 | Technical Data | 65
TIM-ID: 0000045048 - 002