EasyManua.ls Logo

MTU 8V4000Mx4 - Putting the engine into operation after extended out-of-service periods (>3 months)

MTU 8V4000Mx4
278 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2 Putting the engine into operation after extended out-of-service
periods (>3 months)
Preconditions
Engine is stopped and starting disabled.
MTU Preservation and Represervation Specifications (A001070/..) are available.
Putting the engine into operation after extended out-of-service-periods (>3
months)
Item Task
Engine Depreserve (→ Preservation and Represervation Specifications A001070/..).
Lube oil system Check engine oil level (→ Page 219);
Preheat engine oil if required.
Fuel prefilter Prime with fuel (→ Page 205)
Fuel prefilter, pressure
gauge
Align adjustable pointer with position of pressure indicator (→ Page 200).
HP fuel pump Only for engines without oil priming pump:
Fill HP fuel pump with new engine oil (→ Page 184).
Raw-water pump (if located
above waterline (only appli-
cable to engines with en-
gine-mounted heat exchang-
er or with optional remote
heat exchanger))
Prime with water (approx. 3 – 4 l).
Coolant circuit If engine is out of service for more than one year, change engine coolant
(→ Page 235).
Coolant circuit Check coolant level (→ Page 234).
Coolant circuit Preheat coolant with preheating unit.
Engine control system Refer to automation system operating instructions.
ECU Check plug connections (→ Page 257).
EMU Check plug connections (→ Page 258)
EIM Check plug connections (→ Page 259).
MS150109/01E 2015-11 | Operation | 73
TIM-ID: 0000010092 - 005

Table of Contents